What was found
CRACK STRINGER 26L LOCATED STA540 FWD CARGO COMPARTMENT 2024-454443<[01] TOOL USED ON STEP 3 UT EQUIPMENT P/N: 45MG; S/N: 130064101; CAL DUE DATE: 13-DEC-24;[02] EQUIPMENT USED P/N: NORTEC 600D; S/N: 220272512; DUE DATE: 08-JAN-25;[03] TOOL USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 23-JAN-25. TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 23-JAN-25.;[04] PERFORMED PERMANENT REPAIR LOCATED BETWEEN BS500D TO BS 540 AT STR 26L IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 FIGURE 206 SHEET 1 AND TABLE 201. SEE INDIVIDUAL SIGN OFF BELOW.;[05] PERFORMED PERMANENT REPAIR LOCATED BETWEEN BS500D TO BS 540 AT STR 26L IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 FIGURE 206 SHEET 1 AND TABLE 201. SEE INDIVIDUAL SIGN OFF BELOW. RII CERTIFIED