What was found
BROKEN LOWERED CEILING PANEL EMERGENCY LIGHT ASSY AT AFT GALLEY AREA (1 EA) 2024-455064<[01] REPLACED LOWERED CEILING PANEL EMERGENCY LIGHT ASSY AT AFT GALLEY AREA IAW B737-700 AMM 33-51-01-960-802 STEP 3. C. (6)(7) AND (8). <BR>TEST IS OK;[02] REPLACED LOWERED CEILING PANEL EMERGENCY LIGHT ASSY AT AFT GALLEY AREA IAW B737-700 AMM 33-51-01-960-802 STEP 3. C. (6)(7) AND (8). <BR>TEST IS OK