What was found
CRACK INDICATION ON STUB FRAME LOCATED ON BS 294.5 BETWEEN STR-8 TO STR-9 CRACK INDICATION ON STUB FRAME LOCATED ON BS 294.5 BETWEEN STR-8R TO STR-9R IN FORWARD GALLEY DOOR RH SIDE (1 E/A) CRACK LENGTH 0.450 INCH APPROX (2024-455162)<[01] REPLACED STUB FRAME LOCATED ON BS 294.5 BETWEEN STR-8 TO STR-9 IAW B737-700 SRM 51-40-02 ;SRM 51-10-02 ITEM 9 AND DWG 141A8370 SHEET 9;10; 11 REV D. SEE INDIVIDUAL SIGNOFFS BELOW.;[02] CORRECTED STEP 1 <BR>REPLACED STUB FRAME LOCATED ON BS 294.5 BETWEEN STR-8 TO STR-9 IAW B737-700 SRM 51-40-02 ;SRM 51-10-02 ITEM 9 AND DWG 141A8370 SHEET 9;10; 11 REV D FILLED AND LEVELED WITH BMS5-142 IAW BAC5000 AND DWG 141A8370 SHEET 10 FLAGNOTE 9. SEE INDIVIDUAL SIGNOFFS BELOW.;[03] JOB COMPLETED AND CERTIFIED RII