What was found
CRACK WEB LOCATED ON FLOOR STRUCTURE BTW BS312 TO BS328 LBL45 AT FWD GALLEY AREA 2024-512231<[01] REPLACED WEB AND FASTENERS LOCATED ON FLOOR STRUCTURE BTW BS312 TO BS328 LBL45 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02 AND DRAWING: 141A5400 SHEET: 26 REV: -; SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED WEB AND FASTENERS LOCATED ON FLOOR STRUCTURE BTW BS312 TO BS328 LBL45 AT FWD GALLEY AREA IAW B737-800 SRM 51-40-02 AND DRAWING: 141A5400 SHEET: 26 REV: -; SEE INDIVIDUAL SIGN OFF BELOW