What was found
FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I HAS CORROSION AROUND SEVERAL FASTENER HOLES.<[01] BLENDED AREAS OF CORROSION ON FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I; BLENDS ARE OUT OF LIMITS IAW SRM 53-00-53-1A-2.;[02] REMOVED FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I PER SRM 51-40-02.;[03] LOCATED AND DRILL REPLACEMENT FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I PER SRM 51-40-02.;[04] LOCATED AND DRILL REPLACEMENT FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I PER SRM 51-40-02. INSPECTION C/W.;[05] ALODINED AND PRIMED HOLES ON NEW REPLACEMENT R/H TRANSITION ANGLE PER SRM 51-20-01.;[06] ALODINED AND PRIMED HOLES ON NEW REPLACEMENT R/H TRANSITION ANGLE PER SRM 51-20-01. INSPECTION C/W.;[07] OK TO INSTALL.;[08] INSTALLED NEW R/H TRANSITION ANGLE PER SRM 51-40-02;[09] CHANGED CORROSION QUESTION TO YES FOR RII;[10] INSTALLED NEW R/H TRANSITION ANGLE PER SRM 51-40-02. INSPECTION C/W.;[11] REMOVED FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I PER SRM 51-40-02. LOCATED AND DRILL REPLACEMENT FWD CARGO R/H TRANSITION ANGLE STA 500A TO STA 500I PER SRM 51-40-02. INSTALLED NEW R/H TRANSITION ANGLE PER SRM 51-40-02. RII INSPECTION C/W.