What was found
CRACK INDICATION FOUND OF THE STUB FRAME LOCATED BS 290-296 BETWEEN STR8 AND STR9 AT FWD GALLEY DOOR R1 BEAR STRAP. CRACK LENGTH= 0.912 INCHES. 2024-504165<[01] REPLACED STUB FRAME LOCATED BS 290-296 BETWEEN STR8 AND STR9 AT FWD GALLEY DOOR IAW B737-700 SRM 51-40-02 AND DWG: 141A8370; REV . SEE INDIVIDUAL SEGN OF BELOW;[02] CERTIFIED RII WORK PERFORMED. <BR>SEE INDIVIDUAL SIGN OFF BELOW.