What was found
CRACK ON SUPPORT ANGLE LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA 2024-504207<[01] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND DWG 141A1311 SHEET 1 REV C. SEE INDIVIDUAL SIGNS OFF BELOW;[02] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND DWG 141A1311 SHEET 1 REV C. SEE INDIVIDUAL SIGNS OFF BELOW<BR>AS RII