What was found
R/H TRANSITION ANGLE IN FWD CARGO BIN HAS EVIDENCE OF CORROSION STA. 500C TO 500D (MARKED)<[01] REMOVED CORROSION PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2..;[02] BLENDED AREAS; REMOVED .015' MATERIAL; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[03] C/W INSPECTION<BR>C/A#1<BR>C/A#2;[04] CUT OUT AND REMOVED DAMAGE SECTION OF RH TRANSITION ANGLE FOR REPLACEMENT FROM STA 500A TO STA 500F +10 PER SRM 53-00-53-1A.;[05] REMOVED AND REPLACED SECTION OF TRANSITION ANGLE FROM STA. 500A TO 500F + 10 PER SRM 51-40-02. INSTALLED SPLICE REPAIR AT STA 500F+10 PER SRM 53-00-53-2R-5 (REPAIR 5) AND EA M-22-153-01550.;[06] 02 - INSPECTED PER [SRM 53-00-53-2R-5-B00308 (REPAIR 5 - CARGO COMPARTMENT SIDEPLATE REPAIR BETWEEN FLOOR PANEL SPLICES - PERMANENT)] ALSO EA M-22-153-01550