What was found
FWD SERVICE DOOR; CRACK ANGLE AT BS 294.5 STUB FRAME RBL 54 WL 208.1.<[01] REMOVED AND REPLACED CLIP (ANGLE) ON BS.294.5 RBL; 54 WL.208.1 IAW SRM 51-40-02 AND DWG# 141A8310 REV: B. AND REINSTALLED AND APPLIED SEAL AROUND FLOOR PANELS 222AF AND 222BF IAW B-737-700 AMM 53-21-00-400-801. USED Ï¿½Ï¿½TOOL GUN SCREW ID: ATS 1697. EXPIRATION DATE: 07/2025.;[02] VERIFIED CORRECTIVE ACTION ENTRY 1. WITH STEPS 1-4