As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO COMPARTMENT FLOOR PANEL 120CF HAS CORROSION AT FASTENER HOLES<[01] EVALUATED ALLOWABLE LIMITS : CORROSION IS MORE 3.0 IN LENG MAXIMUM PERMITETED FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1<BR>2. FABRICATED NEW PANEL IAW AMM 50-10-04-400-801 AND APPLIED ALODINE ;PRIMER IAW SRM 51-20-02-0G-0 AND AMM 51-21-72-370-804;[02] AUDIT C/W