As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION SPOT AT AFT CARGO FLOOR STRUCTURE RAIL (LBL 3) STA 767 + 5'.<[01] REMOVED DAMAGED PREVIUS REPAIR FABRICATED; LOCATED AND DRILLED NEW REINFORCING CHANNEL MATERIAL BAC1510-1355 7050-T76511 PO# 2084940 AND INSTALLED REPAIR PART (REINFORCING CHANNEL) AT STA 767 + 5' LBL 3 PER REF SRM 53-00-53-2R-2;[02] VERIFIED STEP # 1;[03] VERIFIED STEP#1.