What was found
FWD PIT TRANSITION PANEL AREA; 1 EA ANGLE OF THE INTERCOSTAL HAS A CRACK INDICATION AT BS 500C APPROX LBL-26 (BELOW O/B SIDE OF THE TRANSITION PANEL). MARKED<[01] REMOVED AND REPLACED INTERCOSTAL CLIP WITH NEW PN:143A7502U159 PO: 1099892.3 @ BS 500C APPROX LBL-26 IAW DWG 143A7505 REV -;[02] VERIFIED REMOVED AND REPLACED INTERCOSTAL CLIP WITH NEW PN:143A7502U159 PO: 1099892.3 @ BS 500C APPROX LBL-26 IAW DWG 143A7505 REV -;[03] VERIFIED REMOVED AND REPLACED INTERCOSTAL CLIP WITH NEW PN:143A7502U159 PO: 1099892.3 @ BS 500C APPROX LBL-26 IAW DWG 143A7505 REV -