What was found
FWD PIT L/H TRANSITION PANEL AREA; 1 EA ANGLE OF THE INTERCOSTAL HAS A CRACK INDICATION AT BS 500H APPROX LBL-26 (BELOW O/B SIDE OF THE TRANSITION PANEL). MARKED<[01] REMOVED AND REPLACED FWD PIT L/H ANGLE OF THE INTERCOSTAL AT BS 500H APPROX LBL-26 PN:143A7502U159 PO:1099892.2 IAW DWG 143A7505 REV -;[02] VERIFIED REMOVED AND REPLACED FWD PIT L/H ANGLE OF THE INTERCOSTAL AT BS 500H APPROX LBL-26 PN:143A7502U159 PO:1099892.2 IAW DWG 143A7505 REV -;[03] VERIFIED REMOVED AND REPLACED FWD PIT L/H ANGLE OF THE INTERCOSTAL AT BS 500H APPROX LBL-26 PN:143A7502U159 PO:1099892.2 IAW DWG 143A7505 REV -