What was found
CORROSION FLOOR STRUCTURE STOP FITTING ON BS 312 AT LEVEL STR 17L AND LBL 58 AT FWD GALLEY AREA CORROSION FLOOR STRUCTURE FITTING ON BS 312 AT LEVEL STR 17L AND LBL 58 AT FWD GALLEY AREA 2024-533476<[01] REPLACED FITTING FLOOR STRUCTURE LOC BS 312 AT LEVEL STR 17L AND LBL 58 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02. DUE TO NOT FOUND ALLOWABLE DAMAGE ON SRM 53-10-51-1A-1; IT MUST BE REPLACED. MEASURES ON FITTING LOC BS 312 AT LEVER STR 17 AND LBL 58 AT FWD GALLEY AREA ARE : L: 1.5865 IN W: 0.9680 IN. TOOL USED : DIGITAL CALIPER P/N: 500-197-30 S/N: A21043202 DUE DATE: 13/NOV/2024.;[02] JOB COMPLETED