What was found
CORROSION FLOOR STRUCTURE FITTING BS 344 AND LBL 59 WL 208.1 AT FWD GALLEY AREA 2024-533510<[01] REPLACED FITTING FLOOR STRUCTURE LOC BS 344 AND LBL 59 WL 208.1 AT FWD GALLEY IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02. DUE TO NOT FOUND ALLOWABLE DAMAGE ON SRM 53-10-51-1A-1; IT MUST BE REPLACED. MEASURES ON FITTING LOC BS 344 AND LBL 59 WL 208.1 AT FWD GALLEY AREA ARE : L: 0.7280 IN W: 0.5285 IN. TOOL USED : DIGITAL CALIPER P/N: 500-197-30 S/N: A21043202 DUE DATE: 13/NOV/2024.;[02] JOB COMPLETED