What was found
CRACK INDICATION FOUND ON RT HORIZONTAL STABILIZER LOWER SKIN PANEL. LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB. CRACK LENGTH = 0.900 INCH. APPROX. 2024-533690<[01] TOOL USED ON STEP 5 EDDY CURRENT EQUIPMENT P/N: NORTEC 600D S:N 60009161631 DUE DATE: 11-MAR-25;[02] TOOL USED ON STEP 8: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 210138103; DUE DATE: 10-JUN-25.;[03] REPAIRED RT HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 193.9 RIB AND 16 INCH FROM FRONT SPAR INBOARD SIDE OF RIB I.A.W B737-700 SRM 55-10-01-2R-11 REPAIR 11;[04] CORRECTED STEP 3 <BR>REPAIRED RT HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 193.9 RIB AND 16 INCH FROM FRONT SPAR INBOARD SIDE OF RIB I.A.W B737-700 SRM 55-10-01-2R-11 REPAIR 11<BR>SEE INDIVIDUAL SIGN OFF BELOW;[05] REPAIRED RT HORIZONTAL STABILIZER LOWER SKIN PANEL LOCATED AT STAB STA 193.9 RIB AND 16 INCH FROM FRONT SPAR INBOARD SIDE OF RIB I.A.W B737-700 SRM 55-10-01-2R-11 REPAIR 11<BR>SEE INDIVIDUAL SIGN OFF BELOW. JOB COMPLETED.