What was found
FLAPS WOULD NOT EXTEND PAST 5 WITH 15 SELECTED. FLAPS MOVED TO 15 MANUALLY NO NEEDLE SPLIT NOTED<[01] TROUBLESHOT PER FIM 27-51 TASK 801 & 820; FSEU BITE SHOWS MSG # 27-52260 ; TE FLAP SNSR R. R & R?D RT FLAP POSITION TRANSMITTER & FLAP POSITION INDICATOR PER AMM 27-58-01 & 27-58-02; OPERATIONAL TEST CHECKED GOOD.