What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA312 TO STA344 AND RBL31 FWD GALLEY AND LAV 2024-565236 CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA312 TO STA328 AND RBL31 FWD GALLEY AND LAV<[01] REPLACED WEB - INTERCOSTAL LOC FLOOR STRUCTURE LOCATED BETWEEN STA312 TO STA328 AND RBL31 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02-0G-0 AND DWG 141A5400 SHEET 39 REV: ?;[02] CORRECTED STEP 1.<BR>REPLACED WEB - INTERCOSTAL LOC FLOOR STRUCTURE LOCATED BETWEEN STA312 TO STA328 AND RBL31 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02-0G-0 AND DWG 141A5400 SHEET 39 REV: ?; SEE INDIVIDUAL SIGNOFF BELOW.;[03] CERTIFIED CORRECTIVE ACTION STEP 2