What was found
DOT L7-006: AFT CARGO FLOOR PANEL 140DF HAS CORROSION AT FASTENER HOLES AND ALONG EDGES<[01] UPON FURTHER INVESTIGATION; FOUND THAT CORROSION WAS 25 INCHES IN LENGTH WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS; RECEIVED REPLACEMENT MATERIAL PN 2024-T3-071 A TAG A255451 AND VERIFIED TO BE CORRECT REPLACEMENT MATERIAL; FABRICATED PANEL 140DF; TREATED AND PRIMED PANEL 140DF;[02] UPON FURTHER INVESTIGATION; FOUND THAT CORROSION WAS 25 INCHES IN LENGTH WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS; RECEIVED REPLACEMENT MATERIAL PN 2024-T3-071 A TAG A255451 AND VERIFIED TO BE CORRECT REPLACEMENT MATERIAL; FABRICATED PANEL 140DF; TREATED AND PRIMED PANEL 140DF IAW SRM 53-00-53-1A-1;[03] UPON FURTHER INVESTIGATION; FOUND THAT CORROSION WAS 25 INCHES IN LENGTH WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1; RECEIVED REPLACEMENT MATERIAL PN 2024-T3-071 A TAG A255451 AND VERIFIED TO BE CORRECT REPLACEMENT MATERIAL IAW SRM 53-30-53-0I-1; FABRICATED PANEL 140DF IAW 50-10-04-400-801; TREATED AND PRIMED PANEL 140DF IAW AMM 51-21-41-370-801; AMM 51-21-72-370-801;[04] AUDIT C/W