What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AND BL 0 AT FWD GALLEY AREA 2024-572718<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AND BL 0 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 ; SRM 51-40-02 AND DWG 141A5400 SHEET 20 REV.?<BR>SEE INDIVIDUAL SING-OFF BELLOW.;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE BETWEEN BS 277 TO BS 294.5 AND BL 0 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 ; SRM 51-40-02 AND DWG 141A5400 SHEET 20 REV.?<BR>SEE INDIVIDUAL SING-OFF BELLOW.