What was found
CRACK SLAT 2 I/B AUXILIARY TRACK I/B SUPPORT ANGLE AT LT WING 2024-572734<[01] REPLACED SUPPORT ANGLE LOCATED SLAT 2 I/B AUXILIARY TRACK I/B AT LT WING IAW B737-700 SRM 51-40-02-0G-0 AND MEASURES OF CRACK IS:2.000 INCHES TOOL USED: CALIPER P/N: 500-196-30 S/N: A23352980 DUE DATE: 14/FEB/25.;[02] REPLACED SUPPORT ANGLE LOCATED SLAT 2 I/B AUXILIARY TRACK I/B AT LT WING IAW B737-700 SRM 51-40-02-0G-0 AND MEASURES OF CRACK IS:2.000 INCHES TOOL USED: CALIPER P/N: 500-196-30 S/N: A23352980 DUE DATE: 14/FEB/25.