What was found
CRACK ON SUPPORT ANGLE LOCATE ORSS 270 INTERNAL CAVITY TRAILING EDGE AT LT WING 2024-572791<[01] REPLACED SUPPORT ANGLE LOCATE ORSS 270 INTERNAL CAVITY TRAILING EDGE AT LT WING IAW B737-700 SRM 51-10-02. ITEM 9 ; SRM 51-40-02 <BR>MEASURE OF CRACK : L= 0.900. TOOL USED . DIGITAL CALIPER P/N: 500-196-30. S/N: B23343124 .DUE DATE 09-MAR-25;[02] REPLACED SUPPORT ANGLE LOCATE ORSS 270 INTERNAL CAVITY TRAILING EDGE AT LT WING IAW B737-700 SRM 51-10-02. ITEM 9 ; SRM 51-40-02 <BR>MEASURE OF CRACK : L= 0.900. TOOL USED . DIGITAL CALIPER P/N: 500-196-30. S/N: B23343124 .DUE DATE 09-MAR-25