What was found
CRACK ON SUPPORT ANGLE LOCATED FLOOR STRUCTURE FWD FACE BS 695 BL 0 RT SIDE AT PASSENGER CABIN 2024-571675<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE 23 JAN 25; P/N P3015GOES00000 S/N 112820025 DUE DATE 22 JAN 25.;[02] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED FLOOR STRUCTURE FWD FACE BS 695 BL 0 RT SIDE AT PASSENGER CABIN IAW B737-700 SRM 51-40-02;SRM 51-10-02 DWG 273A9110 SHEET 6 REV A. SEE INDIVIDUAL SIG OFF BELOW.;[03] CORRECTED STEP 2 REPLACED SUPPORT ANGLE (BRACKET)AND FASTENERS LOCATED FLOOR STRUCTURE FWD FACE BS 695 BL 0 RT SIDE AT PASSENGER CABIN IAW B737-700 SRM 51-40-02;SRM 51-10-02 DWG 273A9110 SHEET 6 REV A. SEE INDIVIDUAL SIG OFF BELOW.;[04] COMPLETED JOB