What was found
CRACK ON SUPPORT ANGLE LOCATED FLOOR STRUCTURE BS 695 RBL 24.75 AT PASSENGER CABIN 2024-571802<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE 23 JAN 25; P/N P3015GOES00000 S/N 112820025 DUE DATE 22 JAN 25.;[02] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED FLOOR STRUCTURE BS 695 RBL 24.75 AT PASSENGER CABIN IAW B737-700 SRM 51-40-02;SRM 51-10-02 AND DWG:111A6000;SHEET:284; REV:- SEE INDIVIDUAL SIGN OFF BELOW.;[03] CORRECTED STEP 2 <BR>REPLACED SUPPORT ANGLE (BRACKET) AND FASTENERS LOCATED FLOOR STRUCTURE BS 695 RBL 24.75 AT PASSENGER CABIN IAW B737-700 SRM 51-40-02;SRM 51-10-02 AND DWG:111A6000;SHEET:284; REV:- SEE INDIVIDUAL SIGN OFF BELOW.;[04] COMPLETED JOB