What was found
CRACK INDICATION ON STUB FRAME LOCATED BTW BS 294.5 TO BS 296 AND S-8R TO S-9R AT FWD GALLEY DOOR AREA(1EA). CRACK LENGTH APPROX 1.687 INCH AT PASSENGER CABIN 2024-572141<[01] REPLACED STUB FRAME (1EA) ANGLE (1EA) AND FASTENERS LOCATED BTW BS 294.5 TO BS 296 AND S-7R TO S-10R AT FWD GALLEY DOOR IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG #141A8370 SHEET 9 REV D. SEE INDIVIDUAL SIGNS OFF.;[02] CORRECTED ACTION 1 <BR>REPLACED STUB FRAME (1EA) ANGLE (1EA) AND FASTENERS LOCATED BTW BS 294.5 TO BS 296 AND S-7R TO S-10R AT FWD GALLEY DOOR IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG #141A8370 SHEET 9 REV D. SEE INDIVIDUAL SIGNS OFF BELOW.;[03] TASK CARD COMPLETED AS RII. REPLACED STUB FRAME (1EA) ANGLE (1EA) AND FASTENERS LOCATED BTW BS 294.5 TO BS 296 AND S-7R TO S-10R AT FWD GALLEY DOOR IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG #141A8370 SHEET 9 REV D. SEE INDIVIDUAL SIGNS OFF BELOW.