What was found
CRACKED FLOOR SUPPORT AT BS 394 LBL14 WL208<[01] REMOVED CRACKED FLOOR SUPPORT @ BS380 - BS400 LBL14 WL208 PER SRM 51-40-02-0G-0 AND LOCATED AND DRILLED NEW FLOOR SUPPORT PER DWG: 143A5400 ID: 0182 REV: - AND SRM 51-40-05 AND INSTALLED NEW FLOOR SUPPORT @ BS380-BS400 LBL14 WL208 PER SRM 51-40-02-0G-0 AND DWG: 143A5400 ID: 0182 REV: -;[02] REMOVED CRACKED FLOOR SUPPORT AT BS380 - BS400 LBL14 WL208 PER SRM 51-40-02-0G-0 AND LOCATED AND DRILLED NEW FLOOR SUPPORT PER DWG: 143A5400 ID: 0182 REV: - AND SRM 51-40-05 AND INSTALLED NEW FLOOR SUPPORT AT BS380-BS400 LBL14 WL208 PER SRM 51-40-02-0G-0 AND DWG: 143A5400 ID: 0182 REV: -;[03] VERIFIED STEP 1; CORRECTION ACTION ITEM 3; MEASUREMENT FIELD COMPLETE; CARD COMPLETE.