What was found
CORROSION LOCATED ON FLOOR BEAM 986.5 LBL 42 WL 208.1 AT AFT GALLEY AREA 2024_593057<[01] ET TOOL USED PN: MIZ-21C; SN:769680; DUE DATE: 28-AUG-25;[02] TOOL USED ON STEP 12:ET EQUIPMENT; P/N: NORTEC 600D; S/N:210138003; DUE DATE: 11/JUN/25;[03] PERFORMED PERMANENT REPAIR LOC. ON FLOOR BEAM 986.5 BTW LBL36 TO LBL 46 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 AND SRM 51-40-02. SEE INDIVIDUAL SIGN OFF BELOW;[04] PERFORMED PERMANENT REPAIR LOC. ON FLOOR BEAM 986.5 BTW LBL36 TO LBL 46 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 AND SRM 51-40-02. SEE INDIVIDUAL SIGN OFF BELOW<BR><BR>CERTIFIED AS RII