What was found
CRACK ON STRINGER 16L LOCATED BTW BS 294.5 TO BS 303.9 AT FWD GALLEY AREA 2024-593150<[01] ON STEP 3; TOOL USED ULTRASONIC EQUIPMENT P/N: 45MG; S/N: 130064101; DUE DATE: 13/DEC/24.;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 60009161631; DUE DATE: 11-MAR-25.;[03] PERFORMED PERMANENT REPAIR ON STRINGER 16L LOCATED BTW BS 294.5 TO BS 303.9 AT FWD GALLEY AREA; STRINGER SECTION ;ANGLE 2E/A; CHANNEL 1E/A;IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1.<BR>SEE INDIVIDUAL SIGNS-OFF BELOW;[04] PERFORMED PERMANENT REPAIR ON STRINGER 16L LOCATED BTW BS 294.5 TO BS 303.9 AT FWD GALLEY AREA; STRINGER SECTION ;ANGLE 2E/A; CHANNEL 1E/A;IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1.<BR>SEE INDIVIDUAL SIGNS-OFF BELOW