What was found
CRACK FLOOR STRUCTURE SUPPORT ANGLE LOCATED BS540 AND RBL 2 AT PASSENGER CABIN 2024-600250<[01] REPLACED ANGLE FLOOR STRUCTURE LOCATED STA540<BR>AND RBL2 AT PASSENGER CABIN AND FASTENERS I.A.W B737-<BR>800 SRM 51-10-02 STEP 9 AND DWG: 143A0060 SHEET: 64 REV: - SEE INDIVIDUAL SIGN OFF BELOW;[02] CORRECTED STEP 1: REPLACED ANGLE FLOOR STRUCTURE LOCATED STA540 AND RBL2 AT PASSENGER CABIN AND FASTENERS I.A.W B737-800 SRM 51-10-02 STEP 9 AND DWG: 143A0060 SHEET: 64 REV: - SEE INDIVIDUAL SIGN OFF BELOW;[03] CORRECTED STEP 2: REPLACED ANGLE FLOOR STRUCTURE LOCATED STA540 AND BL0 TO RBL24.75 AT PASSENGER CABIN AND FASTENERS I.A.W B737-800 SRM 51-10-02 STEP 9 AND DWG: 143A0060 SHEET: 64 REV: - SEE INDIVIDUAL SIGN OFF BELOW;[04] REPLACED ANGLE FLOOR STRUCTURE LOCATED STA540 AND BL0 TO RBL24.75 AT PASSENGER CABIN AND FASTENERS I.A.W B737-800 SRM 51-10-02 STEP 9 AND DWG: 143A0060 SHEET: 64 REV: - SEE INDIVIDUAL SIGN OFF BELOW