What was found
DELAMINATED HOLE (2EA) IN ACCESS PANEL 661CB AT RT WING 2024-600552<[01] TOOL USED: CALIPER PN: 500-197-30; SN: B20189521; DUE DATE: 26-JAN-25;[02] TOOL USED: HOT BONDER PN: HCS9200B SN: 15102320; DUE DATE: 25-JAN-25;[03] TOOL USED: SCALE PN: SPX222; SN: C410738991; DUE DATE: 05-AUG-25;[04] TOOL USED: SCALE P/N: CR5200; S/N: 8343110814; DUE DATE: 20-JAN-25.;[05] TOOL USED: HOT BONDER P/N: HCS9200B-AV; S/N: 18196127; DUE DATE: 25-JAN-25.;[06] TOOL USED: ULTRASONIC FLAW DETECTOR P/N: USM GO+; S/N: USMGO11040089; CAL DUE DATE: 21-MAY-25;[07] TOOL USED: HUMIDITY/TEMPERATURE CHART RECORDER P/N: RH550; S/N: 240531238; DUE DATE: 10/SEP/25.;[08] TOOL USED: MULTIMETER P/N: FLUKE 87; S/N: 90160155; DUE DATE: 26-JAN-25.;[09] REPAIRED ACCESS PANEL 661CB AT RT WING IAW B737-800 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGNOFFS BELOW.;[10] REPAIRED ACCESS PANEL 661CB AT RT WING IAW B737-800 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGNOFFS BELOW.