What was found
ON CLIMB OUT F/A NOTICED SMOKE SMELL. NO SMOKE VISIBLE+ SMELL CLEARED AFTER A MINUTE. RAN PACKS FUL COLD BUT DUCT TEMP NEVER WENT BELOW 80 DEGREES. AFTER LANDING- DUCT TEMP RAN AWAY+RT PAC TRIP OFF LIGHT ILLUM TURNED RT PACK OFF FOR TAXI IN. PACK TRIP LT CLEARED<[01] FOUND RIGHT ACM SEIZED. REMOVED AND REPLACED RIGHT ACM PER AMM 21-51-04. PERFORMED OPS CHECK. OPS CHECK GOOD. NO TRIP OFF LIGHT AT THIS TIME. NO SMOKE SMELL IN CABIN AT THIS TIME.