What was found
CRACK STIFFENER FLOOR STRUCTURE LOCATED BS540 BETWEEN BL0 TO RBL 24.75 CENTER SECTION 2024-596932<[01] REPLACED STIFFENER LOC. ON FLOOR STRUCTURE BS540 BETWEEN BL0 TO RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-40-02-0G AND DWG 143A5240 SHEET 3 REV B.;[02] CORRECTED STEP 1. REPLACED STIFFENER LOC. ON FLOOR STRUCTURE BS540 BETWEEN BL0 TO RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-40-02-0G AND DWG 143A5240 SHEET 3 REV B. SEE INDIVIDUAL SIGN OFF BELOW.;[03] REPLACED STIFFENER LOC. ON FLOOR STRUCTURE BS540 BETWEEN BL0 TO RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-40-02-0G AND DWG 143A5240 SHEET 3 REV B. SEE INDIVIDUAL SIGN OFF BELOW.