What was found
R/H A/C BAY AFT WALL UPPER ANGLE TO VAPOR BARRIER CRACKED AT FASTENER HOLE AT APPROX. STA.663; RBL-9'.<[01] SIGNED STEPS 1;2;3 AND 5;[02] INSPECTED WORK ACCOMPLISHED IN C/A #1. TRANSFERED STEPS 1; 2; 3 AND 5 TO SEPERATE FAULTS AS REQURIED PER MPM 52.02.01.;[03] ACCOMPLISHED HFEC HOLE PROBE AND SURFACE INSPECTION OF REPAIR AREA PER NDT PART 6 50-00-00 PROC. 16 AND 51-00-00 PROC. 23 NO DEFECTS NOTED.;[04] NEED OK TO INSTALL REPAIR ANGLE AND SPLICE.;[05] OK TO INSTALL REPAIR ANGLE AND SPLICE. C/A #4;[06] INSTALLED ALL FASTENERS AT VERTICAL FLANGE OF REPAIR ANGLE AND SPLICE PER SRM 57-10-10-2R-5.;[07] C/W RII INSPECTION OF INSTALLED ALL FASTENERS AT VERTICAL FLANGE OF REPAIR ANGLE AND SPLICE PER SRM 57-10-10-2R-5; C/A #6.;[08] C/W RII INSPECTION OF REPAIR INSTALLATION;[09] DAMAGE WAS REPAIRED I.A.W SRM 57-10-10-2R-5. SEE WORK STEPS AND CORRECTIVE ACTIONS FOR INDIVIDUAL WORK ACCOMPLISHED.;[10] C/W INSPECTION