What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727J-747 AROUND FASTENER HOLES.<[01] WORKED CORROSION PER SRM 53-00-53-1A-2.<BR>REMOVED .002 FROM ORIGINAL THK .40<BR>REWORK WITHIN LIMITS;[02] REWORKED AREA OUT OF LIMITS PER SRM 53-00-53-1A-2;[03] VERIFIED C/A #1 AND #2; CORROSION REMOVAL OUT OF LIMITS PER SRM 53-00-53-1A-2.;[04] RH SIDE PLATE TO BE REPLACED FROM STA 727I-767 ON TTG8Q00WHBH5;[05] RH SIDE PLATE TO BE REPLACED FROM STA 727H-767 ON TTG8Q00WHB02;[06] REJECTION ENTERED AS NOTED IN STEP #2;[07] RH SIDE PLATE FROM STA 727H-767 REMOVED AND REPLACED ON TTG8Q00WHB02;[08] INSPECTION CONFIRMS THAT REJECTION NOTED ON STEP #2 HAS BEEN CORRECTED AS REQUIRED PER MPM 51.3.1 AND MPM 51.3.4.2. NO FURTHER ACTION REQUIRED. REJECTION FOUND FAULT CLEARED AT THIS TIME.;[09] RII INSPECTION CONFIRMS THAT THIS FAULT HAS BEEN REPAIRED ON FAULT TTG8Q00WHB02.