What was found
EMERGENCY EXIT LIGHTS REMAIN ON IN ARM POSITION. FOUND BREAKER P18-3 B10 TO BE POPPED. OVERWING EXIT SIGN LIGHT IN CABIN STAYED ON IN THE ARMED POSITION. RESET BREAKER LIGHTS STAYED OFF DURING ARMED POSITION.<[01] REFERENCE WDM 33-51-11 PAGE 10 SHEET 2: EMERGENCY LIGHTS OPERATION CHECKS OK. REFERENCE M/M 33-51-00. SHOOK DOWN CONNECTIONS AT BATTERY PACK ASSEMBLIES M1695; M1671 AND M1672 PER SWPM?NO FAULTS FOUND. REPLACED M1695; M1671 AND M1672 CHARGER ASSEMBLIES AND BATTERY PACKS FOR TROUBLESHOOTING PER M/M 33-51-06. OPS CHECKS OK