What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS277 TO BS 294.5 AND BL 0 FWD GALLEY AND LAV 2024-634311<[01] REPLACED WEB AND FASTENERS BTW BS 270 TO BS 294.5 AT BL 0 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02-0G-0 ITEM 9; SRM 51-40-02-0G AND DWG 141A5400 SHEET:20 REV:-. SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED WEB AND FASTENERS BTW BS 270 TO BS 294.5 AT BL 0 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02-0G-0 ITEM 9; SRM 51-40-02-0G AND DWG 141A5400 SHEET:20 REV:-. SEE INDIVIDUAL SIGN OFF BELOW<BR><BR>RII