What was found
WHILE INSTALLING CARPET FOUND THAT R/H FLOOR PROXIMITY LIGHTING WAS INSTALLED 1 INCH TO FAR AFT.<[01] REMOVED AND RE POSITIONED R/H SIDE PHOTOLUMINESCENT STRIPS IAW AMM 33-51-15-400-899 AND BOEING DWG 417A5775;[02] VERIFIED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE INSTALLING CARPET FOUND THAT R/H FLOOR PROXIMITY LIGHTING WAS INSTALLED 1 INCH TO FAR AFT.<[01] REMOVED AND RE POSITIONED R/H SIDE PHOTOLUMINESCENT STRIPS IAW AMM 33-51-15-400-899 AND BOEING DWG 417A5775;[02] VERIFIED.