What was found
CORROSION ON FLOOR BEAN LOCATED BS 947.5 LBL 50 WL 208.1 AT AFT GALLEY AREA 2024-645560 CORRECTED FAULT NAME: CORROSION ON FLOOR BEAM LOCATED BS 947.5 LBL 50 WL 208.1 AT AFT GALLEY AREA< REMOVED AND REPLACED PARTS PER 737-800 SRM 51-40-02 AS SHOWN IN 15/OCT/20 REFERENCE NRC D166540.;[06] CORRECTED STEP 5 <BR><BR>REMOVED AND REPLACED PARTS PER 737-800 SRM 51-40-02 AS SHOWN IN 15/OCT/20 REFERENCE NRC D166540.<BR>SEE INDIVIDUAL SIGN-OFF BELOW;[07] CORRECTED STEP 6<BR><BR>REPLACED REPAIR PARTS [1] T-CHORD LOC. ON BS947.5 WL208.1 AND LBL 7.8 TO LBL 61 AFT GALLEY AREA IAW B737-800 SRM-53-70-51-2R-5 REPAIR 5 AS SHOWN IN 15/OCT/20 REFERENCE NRC D166540.<BR>SEE INDIVIDUAL SIGN-OFF BELOW.;[08] CORRECTED STEP 7<BR><BR>REMOVED AND REPLACED REPAIR PART [1] T-CHORD LOC. ON BS947.5 WL208.1 AND LBL 7.8 TO LBL 61 AFT GALLEY AREA IAW B737-800 SRM-51-40-02 AS SHOWN IN EA-20-153-02001; ISSUE DATE: 15/OCT/20 REFERENCE NRC D166540.<BR>SEE INDIVIDUAL SIGN-OFF BELOW.;[09] REMOVED AND REPLACED REPAIR PART [1] T-CHORD LOC. ON BS947.5 WL208.1 AND LBL 7.8 TO LBL 61 AFT GALLEY AREA IAW B737-800 SRM-51-40-02 AS SHOWN IN EA-20-153-02001; ISSUE DATE: 15/OCT/20 REFERENCE NRC D166540.<BR>SEE INDIVIDUAL SIGN-OFF BELOW.<BR>RII ITEM