What was found
CORROSION WEB INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA294.5 TO STA312 AND LBL12 WL208.1 AT FWD GALLEY AREA 2024-633641<[01] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN STA294.5 TO STA312 AND LBL12 WL208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND INSTALLED FASTENERS IAW B737-700 SRM 51-40-02 AND DWG 141A5600 SHEET: 1-2 REV: N.<BR>SEE INDIVIDUAL SIGN-OFF BELOW;[02] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN STA294.5 TO STA312 AND LBL12 WL208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND INSTALLED FASTENERS IAW B737-700 SRM 51-40-02 AND DWG 141A5600 SHEET: 1-2 REV: N.<BR>SEE INDIVIDUAL SIGN-OFF BELOW