What was found
CRACK INDICATION FOUND ON RT HORIZONTAL STABILIZER LOWER SKIN PANEL. LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB. CRACK LENGTH = 0.900 INCH. APPROX. 2024-633684<[01] TOOL USED: ET EQUIPMENT; P/N: NORTEC 600D; S/N: 200048001; DUE DATE: 28-MAY-25.;[02] PERFORMED PERMANENT REPAIR LOCATED AT STAB STA 189.4 TO 198.4 BETWEEN FRONT SPAR 12.5 INCHES TO 22 INCHES IAW B737-700 SRM 55-10-01-2R-11REPAIR 11 PARAGRAPH 4 FIG 204 SHEET 2. SEE INDIVIDUAL SIGN OFF BELOW;[03] RII ITEM <BR>PERFORMED PERMANENT REPAIR LOCATED AT STAB STA 189.4 TO 198.4 BETWEEN FRONT SPAR 12.5 INCHES TO 22 INCHES IAW B737-700 SRM 55-10-01-2R-11REPAIR 11 PARAGRAPH 4 FIG 204 SHEET 2. SEE INDIVIDUAL SIGN OFF BELOW