What was found
CORROSION ON INTERCOSTAL LOCATED FLOOR STRUCTURE LOCATED BS328 TO BS 344 AND LBL 12 WL 208.1 AT FWD GALLEY AREA 2024-686163<[01] EQUIPMENT P/N 45MG; S/N 130061901; DUE DATE 12-JUN-25 WAS USED ON STEP 5;[02] REPLACED INTERCOSTAL ON FLOOR STRUCTURE LOCATED BS328 TO BS 344 AND LBL 12 WL 208.1 AT FWD GALLEY AREA IAW. B737-800 SRM 51-10-02-0G-0 ITEM 9 ; SRM 51-40-02-0G-0 AND DWG 141A5400 SHEET 29 REV: - . SEE INDIVIDUAL SIGN-OFF BELOW.;[03] TASK COMPLETED <BR>SEE INDIVIDUAL SIGN-OFF BELOW