What was found
CRACK ON ANGLE LOCATED AT LEVEL STR 8L AND BS 312 AT FWD GALLEY AREA 2024-633958<[01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 23-JAN-25. TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE: 23-JAN-25.;[02] REPLACED ANGLE AND FASTENERS LOCATED AT LEVEL STR 8L AND BS 312 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A8220; SHEET 21 REV A.<BR><BR><BR>SEE INDIVIDUAL SIGN-OFF BELOW.;[03] REPLACED ANGLE AND FASTENERS LOCATED AT LEVEL STR 8L AND BS 312 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A8220; SHEET 21 REV A.<BR><BR>RII CERTIFIED;[04] REPLACED ANGLE AND FASTENERS LOCATED AT LEVEL STR 8L AND BS 312 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A8220; SHEET 21 REV A.<BR><BR><BR>SEE INDIVIDUAL SIGN-OFF BELOW.<BR><BR>RII CERTIFIED