What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED STA695 AND BL0 CENTER SECTION 2024-691553<[01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE 23 JAN 25; P/N 386115K71 S/N AE-40585 DUE DATE 26 JUL 25.;[02] INSTALLED NEW ANGLE FLOOR STRUCTURE LOCATED STA695 AND BL0 CENTER SECTION IAW B737-700 SRM 51-40-02-0G-0 AND DWG 273A9110 SHEET 202 REV - SEE INDIVIDUAL SIGN OFF BELOW.;[03] INSTALLED NEW ANGLE FLOOR STRUCTURE LOCATED STA695 AND BL0 CENTER SECTION IAW B737-700 SRM 51-40-02-0G-0 AND DWG 273A9110 SHEET 202 REV - SEE INDIVIDUAL SIGN OFF BELOW. CERTIFIED AS RII.