What was found
A24-2 AFT PIT FLOOR STRUCTURE STRAP AT DOOR OPENING CORRODED BS 792-847 WL 156 RBL 18<[01] REMOVE CORROSION IAW SRM 51-10-02-0G-0 ITEM 15 AND CHECK WITH 10X MAGNIFYIN GLASS<BR>EVALUATED ALLOWABLE LIMITS 103 ORIG 'T' .084 REMAINING .019 LOSS FOUND OUT OF LIMITS IAW SRM 53-60-15-1A-1 FIG 103<BR>REMOVED DAMAGE STRAP IAW SRM 51-40-02-0G-0<BR>VERIFIED PART USING ATAG WN48987 PART NUMBER 146A8128-14AND 146A8120<BR>REV: A<BR>INSTALLED IAW SRM 51-40-02-0G-0 & BOEING DWG 146A8120 REV: A<BR>APPLIED CIC IAW SRM 53-60-15-2R-1 STEP: 4.B(9);[02] COMPLETE;[03] COMPLETE<BR>AUDIT C/W