As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB APU FLAMED OUT AT 33;000 FEET ; LOW OIL PRESSURE LIGHT ILLUMINATED ; AFTER 5 MINUTES LOW OIL PRESSURE LIGHT EXTINGUISHED . RESTART ATTEMPTED ; APU GENERATOR CAME BACK ONLINE FOR ABOUT 2 MINUTES THEN THE APU FLAMED OUT AGAIN<[01] R&R APU LUBE MODULE REF AMM 49-91-11 OPS & LEAK CHECKS GOOD