As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DOT 7L-009: FWD CARGO FLOOR PANEL 120CF HAS CORROSION AT FATENER HOLES<[01] EVALUATED AREA ON FLOOR PANEL 120CF; DAMAGE REMOVED HAS A MORE THAN 3 INCHES IN LENGHT; MORE OF THE LIMITS PERMITTED; THEREFORE IS OUT OF THE LIMITS I.A.W. SRM 53-00-53-1A-1<BR><BR>FABRICATED NEW FLOOR PANEL 120CF; I.A.W. AMM 50-10-04-400-801;[02] AUDIT C/W