What was found
DOT 7L-018: AFT CARGO FLOOR PANEL 140DF IS CORRODED AT FASTENER HOLES<[01] UPON FURTHER INVESTIGATION FOUND A TOTAL OF 42 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF CORROSION BEING 3 INCHES FOUND PANEL 140DF TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 RECEIVED REPLACEMENT MATERIAL PN 2024-T3-071 A TAG A263956 AND VERIFIED IT TO BE CORRECT REPLACEMENT MATERIAL IAW SRM 53-60-53-0I-1 FABRICATED PANEL 140DF IAW AMM 50-10-04-400-801 TREATED AND PRIMED IAW SRM 51-20-01-0G-0 AND PLACED ON PANEL RACK;[02] UPON FURTHER INVESTIGATION FOUND A TOTAL OF 42 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF CORROSION BEING 3 INCHES FOUND PANEL 140DF TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 RECEIVED REPLACEMENT MATERIAL PN 2024-T3-071 A TAG A263956 AND VERIFIED IT TO BE CORRECT REPLACEMENT MATERIAL IAW SRM 53-60-53-0I-1 FABRICATED PANEL 140DF IAW AMM 50-10-04-400-801 TREATED IAW AMM 51-21-41-370-802 AND PRIMED IAW AMM 51-21-72-370-804 AND PLACED ON PANEL RACK;[03] VERIFIED WORK ACCOMPLISHED.