What was found
CRACK LOCATED ON EGPR SURROUND DOUBLER 2024-763604<[01] STEP 6. EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N: 210138103 AND DUE DATE: 10-JUN-25;[02] PERFORMED PERMANENT REPAIR LOCATED EXTERNAL GROUND ELECTRICAL POWER RECEPTACLE SURROUND DOUBLER BTW BS 227.8 TO BS 235.8 AND BTW STR 21R TO 24R AT LOWER FUSELAGE IAW B737-700 SRM 53-10-15-2R-4 REPAIR 4 ZONE 2 ALTERNATIVE 1 FIGURE 204 SHEET 1 AND 2. SEE INDIVIDUAL SIGN OFF BELOW.;[03] PERFORMED PERMANENT REPAIR LOCATED EXTERNAL GROUND ELECTRICAL POWER RECEPTACLE SURROUND DOUBLER BTW BS 227.8 TO BS 235.8 AND BTW STR 21R TO 24R AT LOWER FUSELAGE IAW B737-700 SRM 53-10-15-2R-4 REPAIR 4 ZONE 2 ALTERNATIVE 1 FIGURE 204 SHEET 1 AND 2. RII VERIFIED