What was found
AFT CARGO; RH SIDEPLATE ALLOWABLE DAMAGE OUT OF LIMITS STA 727H-STA 767<[01] CUT OUT SECTION OF R/H TRANSITION ANGLE BS 727G+10-767 <BR>LOCATED ;TRILLED TREATED AND PRIME PER SRM 53-00-53-2R-5;[02] INSPECTED CUT OUT SECTION OF R/H TRANSITION ANGLE BS 727G+10-767<BR>LOCATED ;TRILLED TREATED AND PRIME PER SRM 53-00-53-2R-5;[03] INSTALLED REPAIR SECTION OF R/H TRANSITION ANGLE BS 727G+10-767 AND COMPLETED REPAIR PER SRM 53-00-53-2R-5.;[04] BRIAN PENCE (TECHNICIAN); 20-DEC-2024 18:00 UTC<BR>INSTALLED REPAIR SECTION OF R/H TRANSITION ANGLE BS 727G+10-767 AND COMPLETED REPAIR PER SRM 53-00-53-2R-5.;[05] BONDED NUT PLATES PER SRM 51-40-10-2R-0<BR>12/20 @ 2100;[06] PREFORMED PUSH TEST PER SRM 51-40-10-2R-0.;[07] 02 - INSPECTED PER [SRM 53-00-53-2R-5-D00308 (REPAIR 5 - CARGO COMPARTMENT SIDEPLATE REPAIR BETWEEN FLOOR PANEL SPLICES - PERMANENT)];[08] 02 - INSPECTED PER [SRM 53-00-53-2R-5-D00308 (REPAIR 5 - CARGO COMPARTMENT SIDEPLATE REPAIR BETWEEN FLOOR PANEL SPLICES - PERMANENT)] (RII)