What was found
CORROSION ON ANGLE FLOOR STRUCTURE LOCATED BS986.5 PLUS 6 INCHES WL208.1 AND LBL36 AT AFT GALLEY AREA 2024-763142<[01] REPLACED ANGLE AND FASTENERS FLOOR STRUCTURE LOCATED BS986.5 PLUS 6 INCHES WL208.1 AND BTW LBL33 TO LBL40 AT AFT GALLEY AREA IAWB737-800 SRM 51-10-02 ITEM 9. AND DRAWING # 147A5700 SHEET 121 REV: A. SEE INDIVIDUAL SIGN OFF BELOW.;[02] CORRECTED STEP 1. REPLACED ANGLE FLOOR STRUCTURE LOCATED BS986.5 PLUS 6 INCHES WL208.1 AND BTW LBL33 TO LBL40 AT AFT GALLEY AREA IAWB737-800 SRM 51-10-02 ITEM 9. AND DRAWING # 147A5700 SHEET 121 REV: A. SEE INDIVIDUAL SIGN OFF BELOW.;[03] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS986.5 PLUS 6 INCHES WL208.1 AND BTW LBL33 TO LBL40 AT AFT GALLEY AREA IAWB737-800 SRM 51-10-02 ITEM 9. AND DRAWING # 147A5700 SHEET 121 REV: A. SEE INDIVIDUAL SIGN OFF BELOW.